Fire Resistance Rating for Gypsum and Kapok Fiber Composite Materials

Authors

  • Mohamad Nor Hishamuddin Manaf School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia
  • Nurul Farhanah Azman School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia
  • Mohamad Nor Musa School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia
  • Syahrullail Samion Institute for Vehicle Systems and Engineering (IVeSE), Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia
  • Nor Azwadi Che Sidik Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia
  • Yutaka Asako Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia

DOI:

https://doi.org/10.37934/arfmts.98.2.1523

Keywords:

Gypsum, Kapok fiber, fire resistance rating

Abstract

Fire rated door is one of the passive fire protection systems that can prevent fire and smoke from spreading when a fire occurs. The purpose of this study was to analyze fire rated doors made of Gypsum and Kapok fiber composites. This fire rated door has been manufactured in accordance with Malaysian Standard MS1073: Part 2: 1996. This fire rated door has been modified with various composite compositions and thicknesses. The results showed that the fire rated door made of Gypsum and Kapok fiber can last from 30 to 60 minutes. This study clearly shows that door thickness is very important in the manufacture of fire rated door.

Downloads

Download data is not yet available.

Author Biographies

Mohamad Nor Hishamuddin Manaf, School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia

mohamad@hotmail.com

Nurul Farhanah Azman, School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia

nurulfarhanahazman@gmail.com

Mohamad Nor Musa, School of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia

mnormusa@utm.my

Syahrullail Samion, Institute for Vehicle Systems and Engineering (IVeSE), Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor, Malaysia

syahruls@mail.fkm.utm.my

Nor Azwadi Che Sidik, Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia

azwadi@utm.my

Yutaka Asako, Malaysia-Japan International Institute of Technology (MJIIT), Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100 Kuala Lumpur, Malaysia

y.asako@utm.my

Downloads

Published

2022-08-06

How to Cite

Mohamad Nor Hishamuddin Manaf, Azman, N. F., Mohamad Nor Musa, Syahrullail Samion, Che Sidik, N. A. ., & Yutaka Asako. (2022). Fire Resistance Rating for Gypsum and Kapok Fiber Composite Materials. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 98(2), 15–23. https://doi.org/10.37934/arfmts.98.2.1523

Issue

Section

Articles