Efficiency Analysis of a Passive Daylighting System Based on Northern Malaysia’s Climate

Authors

  • Mohd Sani Mohamad Hashim Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Muhammad Amin Zulkifli Din Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Abdul Halim Ismail Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Mohd Hafif Basha Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Nasrul Amri Mohd Amin Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Ng Yi Fei Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Muhamad Safwan Muhamad Azmi Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Siti Marhainis Othman Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia
  • Nur Saifullah Kamarrudin Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

DOI:

https://doi.org/10.37934/araset.46.1.107117

Keywords:

Daylighting, Light pipe system, Illuminance measurement, Passive daylighting, Lighting analysis

Abstract

Daylighting design strategy is important in order to have adequate lighting source in a room and necessary to decrease energy consumption for artificial lighting. Passive daylighting system utilizes daylight by collecting, reflecting and diffusing the natural light throughout a given area. The purpose for this study is to monitor, compare and analyse an optimum light pipe system design that can scatter daylight into a room based on three case studies. Lighting analysis was conducted using Autodesk 3ds Max Design software throughout the project based on the actual geographical parameters of Universiti Malaysia Perlis, Malaysia and also using the real sun azimuth on working hours. The results were compared according to the respective designs in order to observe the maximum internal illuminance and the average internal illuminance. The results show that the straight geometry with low aspect ratio produces the highest interior light intensity among other light pipe systems and the average internal illuminance values in the room was able to reach the minimum requirement of a small room which is 200 – 500 lux.

Downloads

Download data is not yet available.

Author Biographies

Mohd Sani Mohamad Hashim, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

sanihashim@unimap.edu.my

Muhammad Amin Zulkifli Din, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

muhammadaminbinzulkifli@gmail.com

Abdul Halim Ismail, Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

ihalim@unimap.edu.my

Mohd Hafif Basha, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

hafifbasha@unimap.edu.my

Nasrul Amri Mohd Amin, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

nasrulamri.mohdamin@unimap.edu.my

Ng Yi Fei, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

yifei_5674@hotmail.com

Muhamad Safwan Muhamad Azmi, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

safwanazmi@unimap.edu.my

Siti Marhainis Othman, Faculty of Electrical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

marhainis@unimap.edu.my

Nur Saifullah Kamarrudin, Faculty of Mechanical Engineering & Technology, Universiti Malaysia Perlis, Pauh Putra Campus, 02600 Arau, Perlis, Malaysia

saifullah@unimap.edu.my

Published

2024-04-26

Issue

Section

Articles

Most read articles by the same author(s)