Experimental Investigation of Modified Direct Evaporative Cooler using Heat Pipe

Authors

  • Bintang Fikri Heat TransferLaboratory, Department of Mechanical Engineering Universitas Indonesia, Kampus UI, Depok 1642, Indonesia
  • Nandy Putra Heat TransferLaboratory, Department of Mechanical Engineering Universitas Indonesia, Kampus UI, Depok 1642, Indonesia
  • Adi Winarta Heat TransferLaboratory, Department of Mechanical Engineering Universitas Indonesia, Kampus UI, Depok 1642, Indonesia
  • Nasruddin A. Abdullah Heat TransferLaboratory, Department of Mechanical Engineering Universitas Indonesia, Kampus UI, Depok 1642, Indonesia
  • Bambang Ariantara Heat TransferLaboratory, Department of Mechanical Engineering Universitas Indonesia, Kampus UI, Depok 1642, Indonesia

Keywords:

Evaporative cooler, Energy Efficiency , Heat and mass transfer, Heat pipe

Abstract

Nowadays, keeping environment at comfort zone with conventional cooler become expensive, especially inwide and semi outdoor spaces. Evaporative cooler which offer a healthy, non-harmful materials, and low cost can be an alternative to keep environment healthy and comfortable. The objective of this experiment is to determine and compare the performance of direct evaporative cooler embedded with heat pipes and without heat pipes. Heat pipes are placed in the section before cooling pad and work as indirect stage. Evaporator sections of heat pipe are placed before cooling pad and the condenser section are placed inthe addition sump.The results showthat the saturation efficiency of both system increase along with the increase in inlet temperature and decrease along with the decrease in relative humidity. The saturation efficiency also decreasesalong with the increase in air velocity. The results also showthat the saturation efficiency of modified evaporative cooler using heat pipe is higher than direct evaporative cooler.Theaddition of heat pipes can increase the saturation efficiency of direct evaporative coolerup to 1.03 without addition more power consumption.

Downloads

Download data is not yet available.

Downloads

Published

2024-03-28

How to Cite

Bintang Fikri, Nandy Putra, Adi Winarta, Nasruddin A. Abdullah, & Bambang Ariantara. (2024). Experimental Investigation of Modified Direct Evaporative Cooler using Heat Pipe. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 55(2), 209–217. Retrieved from https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/3070

Issue

Section

Articles