Assessment of Energy Saving Potential and Lighting System in Teaching Building

Authors

  • Mariah Awang Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Tham C. S Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Nurhanis Mohd Basir Ruddin Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Mohamad Ashraf Abdul Rahman Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Nuramidah Hamidon Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Faridahanim Ahmad Department of Civil Engineering,Universiti Teknologi Malaysia, Skudai, Johor, Malaysia
  • Kamaruzaman Musa Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Sasitharan Nagapan Department of Civil Engineering Technology, Faculty of Engineering Technology, Universiti Tun Hussein Onn Malaysia, 84600 Pagoh, Muar, Johor, Malaysia
  • Mohd Shahril Abdul Rahman Department of Real Estate, Faculty of Built Environment and Surveying,Universiti Teknologi Malaysia, Skudai, Johor, Malaysia

Keywords:

Energy saving, teaching building, facility management, lighting

Abstract

Energy consumption and the potential for energy savings had become more intensive in public buildings in order to improve energy performance. This case study was identified the current occupancy, lighting use patterns and lighting performance in G3 Block B teaching building where most of the teaching rooms were located in University Tun Hussein Onn Malaysia. In order to determine the energy saving potential and strategies for lighting system in the building, a series of data collection were conducted to the effects of occupancy and lighting use patterns to display the lighting energy consumption and lighting energy waste of the case study building. The findings of this study displayed lighting use patterns varied among all the investigated lecture rooms at which 31% of lighting load was wasted and 13% of lighting load misused bythe building users were recorded. Moreover, the result of lighting performance of the lecture room obtained was met the recommended average illuminance level (300-500 lux) of lighting for working interiors as classroom in MS 1525:2007. In addition, the perception, awareness and practices of energy conservation behavior on lighting of the building user were also studied through structured questionnaire. With regard to the findings of questionnaire in this study, the responses indicated that most of the respondents agreed they were at good perception, awareness and practices on their energy conservation behavior on lighting. Based on the various data obtained in this project, the energy and cost saving potential strategies were suggested for instances the structural energy conservation measures and non-structural energy conservation measures to improve the usage and efficiency of the lighting system in the teaching building towards energy conservation.

Downloads

Download data is not yet available.

Downloads

Published

2024-03-28

How to Cite

Mariah Awang, Tham C. S, Nurhanis Mohd Basir Ruddin, Mohamad Ashraf Abdul Rahman, Nuramidah Hamidon, Faridahanim Ahmad, Kamaruzaman Musa, Sasitharan Nagapan, & Mohd Shahril Abdul Rahman. (2024). Assessment of Energy Saving Potential and Lighting System in Teaching Building. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 65(1), 159–169. Retrieved from https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/3702

Issue

Section

Articles