Numerical Simulation of Alternative Smoke Control Approach in a High-Rise Building

Authors

  • Jonathan Ho Siew Kit Department of Mechanical Engineering, Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus,Jalan Simpang Tiga, 93300 Kuching, Sarawak, Malaysia
  • Chong Kok Hing Department of Mechanical Engineering, Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus,Jalan Simpang Tiga, 93300 Kuching, Sarawak, Malaysia
  • Basil T. Wong Department of Mechanical Engineering, Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus,Jalan Simpang Tiga, 93300 Kuching, Sarawak, Malaysia
  • Victor Bong Nee Shin Department of Mechanical Engineering, Faculty of Engineering, Computing and Science, Swinburne University of Technology Sarawak Campus,Jalan Simpang Tiga, 93300 Kuching, Sarawak, Malaysia
  • Lee Man Djun School of Engineering and Technology, University College of Technology, 96000 Sibu, Sarawak, Malaysia
  • Christopher Jantai Anak Boniface Public Works of Department, Wisma Saberkas Building, Tun Abang Haji Openg Road, 93582, Kuching, Sarawak, Malaysia

Keywords:

Numerical simulation, smoke control, high-rise building, ACMV, louver

Abstract

Smoke inhalation is a major cause of death in fire accident. Three quarters of building fire casualties were the result of excessive smoke inhalation, even with the presence of a control system. One of the main reasons to a high percentage of fatality is poor circulation and exhaustion of smoke. A proposed system, including an integrated ACMV exhaust with additional louver, will be simulated and compared with the current conventional approach, the fixed pressurization system. The purpose of this study is to determine the effectiveness of the newly proposed approach to smoke exhaustion. Results showed that the path of obscuration for the conventional system in the room displayed a lowered value of 8.77 %, as compared to 9.71% for the integrated ACMV system, due to the greater propagation of smoke out of the room. The results are in agreement as there is a noticeably faster subsiding of hot air temperature at the corridor for the integrated ACMV system than that of the conventional system, after the peak temperature spread of 115 seconds. The current study concluded that the proposed integrated ACMV system with additional louver is more effective for smoke control than the conventional design.

Downloads

Download data is not yet available.

Downloads

Published

2024-03-28

How to Cite

Jonathan Ho Siew Kit, Chong Kok Hing, Basil T. Wong, Victor Bong Nee Shin, Lee Man Djun, & Christopher Jantai Anak Boniface. (2024). Numerical Simulation of Alternative Smoke Control Approach in a High-Rise Building. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 80(2), 1–12. Retrieved from https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/7341

Issue

Section

Articles