The Optimum Thickness of Rockwool as Roof Thermal Insulation: An Experimental and Numerical Study

Authors

  • Mohammed W. Muhieldeen Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia
  • Lim Chong Lye School of Engineering and Technology, PSB Academy, Singapore
  • Mohammed Sameer Sharaf Kassim Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia
  • Wah Yen Tey Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia
  • Kah Hou Teng UCSI-Cheras Low Carbon Innovation Hub Research Consortium, Kuala Lumpur, Malaysia

DOI:

https://doi.org/10.37934/arfmts.89.1.7791

Keywords:

Saving Energy, Rockwool Insulation, Optimum Thickness, tropical climate, CFD

Abstract

Now a days, the global warming has increased the temperature in the environment that forced the building occupant to get assisting from the air condition to reduce the heat tension inside the building, this could increase the electricity bill amount. The aim of this study is to measure the optimum thickness of Rockwool insulation to experimentally and numerically to reduce the heating load inside the buildings. Two devices have been used through this research, Infrared Thermometer to measure profile temperature of the walls along with VELOCICALC to measure the air temperature and air velocity. Three different layers of Rockwool insulation have been applied on the roof of wooden room. The data present the two layers thickness of Rockwool is the best selection to reduce the heating load inside the room, the differential between outside and inside is 0.9 °C, the Rockwool of one layer reduced only 0.5 °C and the maximum thickness with three layers reduced only 1 °C, which is not much effective compared to the two layers but even more costly. CFD analysis shows agreement with the experimental result. The results shows if the dimensions of a UCSI lecture room is to be considered, then applying Rockwool insulation with a thickness of 100 mm would cost around RM 1520 as a UCSI lecture room is of 8 m width and 9 m length. However, two layers of Rock wool insulation could save around 29.30% of ROI per annum.

Author Biographies

Mohammed W. Muhieldeen, Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia

al-gailani@ucsiuniversity.edu.my

Lim Chong Lye, School of Engineering and Technology, PSB Academy, Singapore

chonglye.lim@psb-acdemy.edu.sg

Mohammed Sameer Sharaf Kassim, Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia

engr.mohammedsameer@gmail.com

Wah Yen Tey, Mechanical Engineering Department, Faculty of Engineering, Technology & Built Environment, UCSI University, Cheras, Malaysia

teywy@ucsiuniversity.edu.my

Kah Hou Teng, UCSI-Cheras Low Carbon Innovation Hub Research Consortium, Kuala Lumpur, Malaysia

tengkh@ucsiuniversity.edu.my

Downloads

Published

2022-01-01

How to Cite

Mohammed W. Muhieldeen, Lim Chong Lye, Kassim, M. S. S. ., Wah Yen Tey, & Kah Hou Teng. (2022). The Optimum Thickness of Rockwool as Roof Thermal Insulation: An Experimental and Numerical Study. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 89(1), 77–91. https://doi.org/10.37934/arfmts.89.1.7791

Issue

Section

Articles

Most read articles by the same author(s)