Combination of Dehumidifier, Heat Pump and Air Heater: Influence of Temperature, Specific Humidity, And Mass Flow Rate of Air on Specific Energy Consumption

Authors

  • Ahmad Zikri Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia
  • Engkos Achmad Kosasih Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia
  • Muhammad Irfan Dzaky Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia
  • Firdaus Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia

Keywords:

Drying, specific energy consumption, relative humidity, refrigeration, heat pump

Abstract

Drying is the process of transferring heat and mass to remove water by heat application, from solid or liquid food, to decrease water content. The temperature and drying conditions imposed on a product have an essential influence on it. Drying in high temperatures can cause damage the sensitive materials. To overcome this problem, in this paper, to show the effect of temperature, specific humidity and massflow rate, on the specific energy consumption on the use of air heaters, and the combination refrigeration system to produce hot and dry air. In this study, we use an experimental method by using temperature variations of 60°C, 90°C, 120°C, and 150°C. Air mass flow rates using 100 Lpm, 150 Lpm, 200 Lpm, and 250 Lpm variation. The air from the environment is sucked up by the blower and then enters the evaporator. In the evaporator, the air will condensate so the air will get the low relative humidity. The heat in the condenser is used as preheating the dry air before entering the heater. To produce hot and dry air with the minimum humidity ratio (3.9 g / kg dry air) for the same target temperature is recommended to use a 100Lpm airflow rate by adjusting the evaporator pressure to 2.6 bar. Then, to obtain the minimum SECR (0.928), the recommended target temperature is 120°C, by adjusting the airflow rate to 250Lpm and the pressure at the evaporator 1.6 bar.

Downloads

Download data is not yet available.

Downloads

Published

2024-03-28

How to Cite

Ahmad Zikri, Engkos Achmad Kosasih, Muhammad Irfan Dzaky, & Firdaus. (2024). Combination of Dehumidifier, Heat Pump and Air Heater: Influence of Temperature, Specific Humidity, And Mass Flow Rate of Air on Specific Energy Consumption. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 76(1), 124–134. Retrieved from https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/6954

Issue

Section

Articles