Exhaust Gas Pressure and Flow Velocity Analysis of the Conical Silencer High Performance Low Noise Exhaust Muffler

Authors

  • Ahmad Roziqin Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia
  • Sonika Maulana Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia
  • Kriswanto Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia
  • Angga Septiyanto Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia
  • M. Irfan Khoirurroziqin Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia
  • Ahmad Nasirudin Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

DOI:

https://doi.org/10.37934/arfmts.109.2.3948

Keywords:

Flow pressure, flow velocity, conical silencer muffler, OEM muffler, free flow muffler

Abstract

This study aims to determine the exhaust gas pressure and flow velocity of the conical silencer muffler compared to various types of muffler commonly used in the market. Conical silencer muffler developed to obtain high performance and low noise for internal combustion engine. Analysis of flow velocity and pressure used CFD method, the input fluid velocity parameter of 12000 mm/s with Siemens NX 10 software. Four exhaust mufflers have been designed in this study, conical silencer muffler, free flow muffler, a db killer installed in free flow muffler, and OEM muffler. The results of the analysis that have been carried out shown the conical silencer muffler has a max flow rate of 31200 mm/s with a pressure of 0.713 KPa, the OEM muffler has a flow rate of 47500 mm/s with a pressure of 4.250 KPa, the free flow muffler has a flow rate of 26500 mm/s with a pressure of 0.471 KPa, while the free flow muffler with db killer has a flow rate of 123000 mm/s with a pressure of 28.4 KPa. Based on these data, the performance of the free flow muffler was used as a benchmark for the performance of other mufflers. Conical silencer muffler has a flow difference of 4700 mm/s (18%) and a pressure difference of 0.24 KPa (51%) higher than free flow muffler, OEM muffler has a higher flow difference of 21000 mm/s (79%) and a pressure difference of 3.78 KPa (802%), free flow muffler with db killer has a higher flow difference of 96500 mm/s (364%) and a pressure difference of 27.93 KPa (5930%) compared to free flow muffler. Based on these data, it can be concluded the conical silencer muffler can generate performance near to the free flow muffler.

Author Biographies

Ahmad Roziqin, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

ar_unnes@mail.unnes.ac.id

Sonika Maulana, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

sonika@mail.unnes.ac.id

Kriswanto, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

kriswanto@mail.unnes.ac.id

Angga Septiyanto, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

anggatm@mail.unnes.ac.id

M. Irfan Khoirurroziqin, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

muh.irfan@students.unnes.ac.id

Ahmad Nasirudin, Mechanical Engineering Department, Universitas Negeri Semarang, Indonesia

akhnasirudin@students.unnes.ac.id

Downloads

Published

2023-11-17

How to Cite

Ahmad Roziqin, Sonika Maulana, Kriswanto, Angga Septiyanto, M. Irfan Khoirurroziqin, & Ahmad Nasirudin. (2023). Exhaust Gas Pressure and Flow Velocity Analysis of the Conical Silencer High Performance Low Noise Exhaust Muffler. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 109(2), 39–48. https://doi.org/10.37934/arfmts.109.2.3948

Issue

Section

Articles

Most read articles by the same author(s)