A Cost-effective Data Acquisition Instrumentation for Measurement of Base Pressure and Wall Pressure in Suddenly Expanded Flow Through Ducts

Authors

  • Vigneshvaran Sethuraman School of Aerospace Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
  • Parvathy Rajendran School of Aerospace Engineering, Universiti Sains Malaysia, 14300 Nibong Tebal, Penang, Malaysia
  • Sher Afghan Khan Department of Mechanical Engineering, International Islamic University Malaysia, 53100 Kuala Lumpur, Malaysia

Keywords:

Base pressure, data acquisition, internal flow measurements, sudden expansion, wall pressure

Abstract

Internal flow experimental studies such as sudden expansion in ducts have been reported in literature. However, the methodology of arriving at the results is not discussed elaborately with accent on cost involved and time spent in acquiring the data. This paper explains in detail about the experimental procedure, the methodology of arriving at results and the data analysis. The experimental setup with readily available commercial data acquisition instrumentation for a typical sudden expansion internal flow is presented. It was observed that apart from the cost of hardware fabrication, the cost of instrumentation and measuring devices is also huge. This is apparent especially in fluid flow problems, wherethere is a need to measure pressures at multiplelocations. However, commercially available DAQs have a limited number of channels. Thus, the need for an alternativecost-effective data acquisition system (DAQ) with multiple channels is crucial. Hence, an alternate arrangement of DAQ which is considerably cost-effective and is equally efficient as that of commercial instrumentis proposed. The base pressure and wall pressure results obtained using fabricated DAQ had a variation of ± 1% and ± 1.5% respectively, in comparison to that of commercial DAQ. It is reported that these two arrangements give comparable results with very good accuracy and repeatability of results.

Downloads

Published

2024-03-28

How to Cite

Vigneshvaran Sethuraman, Parvathy Rajendran, & Sher Afghan Khan. (2024). A Cost-effective Data Acquisition Instrumentation for Measurement of Base Pressure and Wall Pressure in Suddenly Expanded Flow Through Ducts. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 60(1), 112–123. Retrieved from https://semarakilmu.com.my/journals/index.php/fluid_mechanics_thermal_sciences/article/view/3452

Issue

Section

Articles

Most read articles by the same author(s)

1 2 3 > >>