CFD Analysis for Valve-Holding Camber Permanent Inhaler Spacer (AerospaAcer) with Different Valves

Authors

  • Riyadhthusollehan Khairulfuaad Department of Aeronautical Engineering, Fakulti Kejuruteraan Mekanikal, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, Malaysia
  • Norzelawati Asmuin Department of Aeronautical Engineering, Fakulti Kejuruteraan Mekanikal, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, Malaysia
  • Juntakan Taweekun Department of Mechanical and Mechatronics Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai, Thailand
  • Azizan Ismail Department of Aeronautical Engineering, Fakulti Kejuruteraan Mekanikal, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, Malaysia
  • Nabil Izzuddin Shahhidan Department of Aeronautical Engineering, Fakulti Kejuruteraan Mekanikal, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, Malaysia

DOI:

https://doi.org/10.37934/cfdl.16.6.5367

Keywords:

Computational Fluid Dynamic (CFD), Flow characteristic, Metered- dose inhaler spacer, Valve-Holding Chamber

Abstract

During the COVID-19 pandemic, data statistics showed that patients with respiratory problems become infected. One of the therapy techniques for the respiratory condition was the use of a metered-dose inhaler and spacer. The objective of this paper is to determine the flow parameters of three types of valves which is duckbill valve, cross slit valve and umbrella valve in inhaler spacer to compare fluid flow between valve Previous researchers chose the duckbill valve to control fluid flow in inhaler spacer. The flow characteristics are unaffected by the materials used in the new disposable inhaler spacers, such as paper and polylactic acid (PLA). Several design valves reduced the skewness below 0.94 by suppressing the fillet and chamfer. ANSYS Workbench Fluent 19.2 is used to calculate flow parameters such as turbulence kinetic energy (TKE), turbulence eddy dissipation (TED), velocity, particle velocity magnitude, streamline, and vector velocity. The setup input data is based on the previous researcher's specified parameters such as viscosity model, drug characteristics (salbutamol and propellant), discrete phase model (DPM) equal to 80, boundary condition model, and SIMPLE technique. For the three types of valves, the nozzle injection used a 0.50-millimetre dimension. The simulation work is cross-checked against the results of prior simulations. Within each iteration, the transient flow employed a time step size of 0.01 for 200 steps. The results show that computational analysis can distinguish between models of varying complexity. The TED, TKE, and velocity graphs showed the approximate value between the model geometries. Overall, the study was successful in achieving the desired velocity magnitude in terms of visual and graph representations of the various valve.

Downloads

Download data is not yet available.

Author Biography

Norzelawati Asmuin, Department of Aeronautical Engineering, Fakulti Kejuruteraan Mekanikal, Universiti Tun Hussein Onn Malaysia, 86400 Batu Pahat, Johor, Malaysia

norzela@uthm.edu.my

References

Amini, Shahideh, Arezou Ghasemi, Mohammad Solduzian, Besharat Rahimi, Kazem Heidari, Molouk Hadjibabaie, and Mona Kargar. "Is Inhaler Technique Associated with Quality of Life in Patients with Chronic Obstructive Pulmonary Disease?." Current Therapeutic Research 93 (2020): 100608. https://doi.org/10.1016/j.curtheres.2020.100608

Chen, Annie T., Shaoqing Ge, Susie Cho, Andrew K. Teng, Frances Chu, George Demiris, and Oleg Zaslavsky. "Reactions to COVID-19, information and technology use, and social connectedness among older adults with pre-frailty and frailty." Geriatric nursing 42, no. 1 (2021): 188-195. https://doi.org/10.1016/j.gerinurse.2020.08.001

Delikhoon, Mahdieh, Marcelo I. Guzman, Ramin Nabizadeh, and Abbas Norouzian Baghani. "Modes of transmission of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) and factors influencing on the airborne transmission: A review." International journal of environmental research and public health 18, no. 2 (2021): 395. https://doi.org/10.3390/ijerph18020395

Duke, Daniel J., Dung T. Nguyen, Larissa Gomes Dos Reis, Dina M. Silva, Adrian Neild, Daniel Edgington-Mitchell, Paul M. Young, and Damon R. Honnery. "Increasing the fine particle fraction of pressurised metered dose inhaler solutions with novel actuator shapes." International Journal of Pharmaceutics 597 (2021): 120341. https://doi.org/10.1016/j.ijpharm.2021.120341

Abd Rahman, Muhammad Faqhrurrazi, Nor Zelawati Asmuin, Ishkrizat Taib, Juwaidi Nazar, Azizan Ismail, and Riyadhthusollehan Khairulfuaad. "Investigate flow characteristics of metered-dose inhaler (MDI) disposable inhaler spacer (AeroCup) for COVID-19 patient by using computational fluid dynamic (CFD)." CFD Letters 12, no. 12 (2020): 63-74. https://doi.org/10.37934/cfdl.12.12.6374

Jeswani, Harish Kumar, and Adisa Azapagic. "Life cycle environmental impacts of inhalers." Journal of Cleaner Production 237 (2019): 117733. https://doi.org/10.1016/j.jclepro.2019.117733

Kerwin, Edward M., Andrew Preece, Dimitra Brintziki, Kathryn A. Collison, and Raj Sharma. "ELLIPTA dry powder versus metered-dose inhalers in an optimized clinical trial setting." The Journal of Allergy and Clinical Immunology: In Practice 7, no. 6 (2019): 1843-1849. https://doi.org/10.1016/j.jaip.2019.02.023

Kesten, Steven, Elliot Israel, Guangxi Li, Jolyon Mitchell, Robert Wise, and Tom Stern. "Development of a novel digital breath-activated inhaler: Initial particle size characterization and clinical testing." Pulmonary Pharmacology & Therapeutics 53 (2018): 27-32. https://doi.org/10.1016/j.pupt.2018.08.007

Kofman, Carlos, and Alejandro Teper. "Usefulness of Nonvalved Spacers for Administration of Inhaled Steroids in Young Children with Recurrent Wheezing and Risk Factors for Asthma." Canadian Respiratory Journal 2018 (2018). https://doi.org/10.1155/2018/3095647

Lavorini, Federico, Celeste Barreto, Job FM van Boven, Will Carroll, Joy Conway, Richard W. Costello, Birthe Hellqvist Dahl et al. "Spacers and valved holding chambers—the risk of switching to different chambers." The Journal of Allergy and Clinical Immunology: In Practice 8, no. 5 (2020): 1569-1573. https://doi.org/10.1016/j.jaip.2019.12.035

Mat, Mohamad Nur Hidayat, Nor Zelawati Asmuin, Nor Halim Hasan, Hanis Zakaria, Muhammad Faqhrurrazi Abd Rahman, Riyadhthusollehan Khairulfuaad, and Balasem Abdulameer Jabbar. "Optimizing dry ice blasting nozzle divergent length using CFD for noise reduction." CFD Letters 11, no. 6 (2019): 18-26.

Pope III, C. Arden, Joseph B. Muhlestein, Heidi T. May, Dale G. Renlund, Jeffrey L. Anderson, and Benjamin D. Horne. "Ischemic heart disease events triggered by short-term exposure to fine particulate air pollution." Circulation 114, no. 23 (2006): 2443-2448. https://doi.org/10.1161/CIRCULATIONAHA.106.636977

Abd Rahman, Muhammad Faqhrurrazi, Nor Zelawati Asmuin, Ishkrizat Taib, Mohamad Nur Hidayat Mat, and Riyadhthusollehan Khairulfuaad. "Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD." CFD Letters 12, no. 6 (2020): 67-79. https://doi.org/10.37934/cfdl.12.6.6779

Abd Rahman, Muhammad Faqhrurrazi, Norzelawati Asmuin, Nurul Fitriah Nasir, Ishkrizat Taib, Mohamad Nur Hidayat Mat, and Riyadhthusollehan Khairulfuaad. "Effect of Different Orifice Diameter on The Flow Characteristic in Pressurized Metered Dose Inhaler by Using CFD." CFD Letters 12, no. 3 (2020): 39-49. https://doi.org/10.37934/cfdl.12.3.3949

Abd Rahman, Muhammad Faqhrurrazi, Suzairin MD Seri, Nor Zelawati Asmuin, Ishkrizat Taib, and Nur Syakirah Rabiha Rosman. "Response Surface Methodology (RSM) Approach for Optimizing the Actuator Nozzle Design of Pressurized Metered-Dose Inhaler (pMDI)." CFD Letters 13, no. 7 (2021): 27-44. https://doi.org/10.37934/cfdl.13.7.2744

Torén, Kjell, Ingvar A. Bergdahl, Tohr Nilsson, and Bengt Järvholm. 2007. “Occupational Exposure to Particulate Air Pollution and Mortality Due to Ischaemic Heart Disease and Cerebrovascular Disease.” Occupational and Environmental Medicine 64 (8): 515–19. https://doi.org/10.1136/oem.2006.029488

Wang, Sanwang, Xin Wen, Yingying Dong, Bin Liu, and Minghu Cui. "Psychological influence of coronovirus disease 2019 (COVID-19) pandemic on the general public, medical workers, and patients with mental disorders and its countermeasures." Psychosomatics 61, no. 6 (2020): 616-624. https://doi.org/10.1016/j.psym.2020.05.005

Wang, Xiao-Rong, and David C. Christiani. "Respiratory symptoms and functional status in workers exposed to silica, asbestos, and coal mine dusts." Journal of occupational and environmental medicine (2000): 1076-1084. https://doi.org/10.1097/00043764-200011000-00009

Downloads

Published

2024-01-23

How to Cite

Riyadhthusollehan Khairulfuaad, Norzelawati Asmuin, Juntakan Taweekun, Azizan Ismail, & Nabil Izzuddin Shahhidan. (2024). CFD Analysis for Valve-Holding Camber Permanent Inhaler Spacer (AerospaAcer) with Different Valves. CFD Letters, 16(6), 53–67. https://doi.org/10.37934/cfdl.16.6.5367

Issue

Section

Articles

Most read articles by the same author(s)